X-CELL INVERTER SPECIFICATION

SPECIFICATION

Input voltage 10.8 - 16 volts dc. (12 volt input)
Output voltage 230 volts -/+10% 50 Hz (standard)
Size 348.5 width (including mounting feet) 210 depth x 129.8 high [mm].
Weight : 500w 8.4Kg, 750w 9.3Kg, 1000w 10.7Kg, 1500w 12.95Kg.
Input connection via 2 x M8 studs on rear of unit.
Output via 2 x 13 Amp sockets (standard).
Alarm indication by single red led on front panel.
Power on/off switch on front panel.
Remote operation and indication via 9 pin socket on rear of case.

MODE OF OPERATION


The low dc voltage is converted into a quasi sine wave using solid state power electronic devices, the frequency of the output voltage is crystal controlled for accuracy and stability. The dc input voltage is sampled in order to detect either a low or a high input and generates an alarm signal plus an output drive shutdown. Similarly the internal heat sink temperature is monitored and if a high temperature is detected an alarm signal plus an output drive shutdown occurs until the temperature has dropped to a safe level when the unit will automatically switch back on. The dc input current draw is measured in order to detect an overload, if an overload exists an alarm plus an output drive shutdown is generated. If during the slow start switch on an overload is generated the unit will continue to generate the alarm/shut down signal until the overload is reduced. 

Click here for Contact Information