X-ACT SPECIFCATION

Click on any of the buttons for further information.
Last update 15/09/2010


ELECTRICAL


Input: 12.8 - 14.2 volts for 12 volt systems.
Input: 25 - 30 volts for 24 volts systems.
Output for 12 volts systems: regulated to 12.2 or 12.6 volts DC over the input range. (standard models)
Output for 24 volts systems: regulated to 24.5 volts DC over the input range. (standard models)
Current capacity: 5 Amps, 25 Amps, 50 Amps and 100 Amps.
Over current protection provided by manual reset magnetic/hydraulic current trip on 50 and 100 Amp versions.
Transient suppression circuit to "clean" voltage spikes on 24 volt versions.
Maximum ambient temperature 35ºC.
CE approved.


MECHANICAL


Dimensions 5 Amp versions:147 l x 95 w x 35 h (mm) aluminium case with 2 fixing flanges.
Dimensions 12 volt 15 Amp & 25 Amp versions: 140 l x 170 w x 135 h (over studs) (mm) aluminium extrusion with 2 fixing flanges.
Dimensions 12 volt 50 Amp: & 24 volt 25 Amp versions: 160l x 170w x 135h (over studs) mm. extrusion with 2 fixing flanges.
Dimensions 12 volt 100 Amp & 24 volt 50 & 100 Amp versions: 240 l x 150 w x 135 h (mm) mild steel case with 2 fixing flanges.
Weight 5 Amp: 0.33Kg.
Weight 15 & 25 Amp: 2.2Kg.
Weight 50 & 100 Amp: 3.9Kg.
Cooling 5 Amp, 15 Amp  & 25 Amp: Convection cooling.
Cooling 12 volt 50 Amp & 24v 25 volt 50 Amp: one off 12/24 volt, temperature controlled fan set to switch on at 50ºC and switch off when unit cooled to 35ºC.
Cooling 12 volt 100 Amp, 24 volt 50 & 100 Amp: two off 12/24 volt, temperature controlled fans set to switch on at 70ºC and switch off when unit cooled to 45ºC.
Wiring connections 5 Amp: 300 mm Tri rated 24/02 cable for power and 300 mm 16/02 for electronics 0v.
Wiring connections 15 Amp, 25 Amp & 50 Amp (12  volt): M6 Brass Ni plated studs for power connections and M4 stud for electronics 0v.
Wiring connections 50 & 100 Amp: Power connections to M8 and output sense and 0v electronics via M4 studs.


Click here for Contact Information